Knowledge Network Node

高速铁路铜镁合金弹性吊索失效分析

袁远肖柱马牧之

中国铁道科学研究院集团有限公司标准计量研究所中南大学材料科学与工程学院

Abstract: The micro-morphology of the elastic sling sample of copper-magnesium alloy broken during operation was observed by scanning electron microscope and metallographic microscope, the corrosion products on the surface of the sample were analyzed by energy dispersive spectrometer, and the simulation test of cold pressing welding of copper-magnesium alloy was carried out.Determine the abnormal structure at the fracture of the material. The results show that the failure mode of the sample is corrosion f... More
  • DOI:

    10.19981/j.CN23-1581/G3.2023.16.018

  • Series:

    (C) Architecture/ Energy/ Traffic/ Electromechanics, etc

  • Subject:

    Railway Transportation

  • Classification Code:

    U238;U225

Download the mobile appuse the app to scan this coderead the article.

Tips: Please download CAJViewer to view CAJ format full text.

Download: 257 Page: 75-78 Pagecount: 4 Size: 1464K